Enhancement of transdermal absorption of drugs by pulsed output ultrasound :
Effect of radiating area and frequency
Junji AsanoToshiharu OheNaoko KawasakiShozo Miyazaki
Author information
JOURNAL FREE ACCESS

1998 Volume 13 Issue 3 Pages 185-189

Details
Abstract

The effect of radiating area and frequency of pulsed output ultrasound with an on/off ratio of 1 : 2 on transdermal absorption of indomethacin from an ointment was studied in rats. Ultrasonication was produced by a commercially available ultrasound system approved for human use which has two different sizes of transducer, large head (4.4 cm2) and small head (0.7 cm2). We did not find any difference in transdermal absorption of indomethacin between two transducer (effective radiating areas). Ultrasound should be generated by a small head since a small head enalbes the rats to administer the treatment. The frequency of the pulsed ultrasound was suggested to play an important role in the transdermal phonophoretic delivery system of indomethacin ; 1 MHz appeared to be more effective than 3 MHz in improving the transdermal absorption.