Abstract
Steady state current of nematic liquid crystal cells has been measured. The experimental results show that there is no thickness dependence for the sample cell using no aligning layer; and for the sample cell using poly-imide aligning layer, current depends on cell thickness: thicker rigion, current is proportional to inverse of thickness, and thinner rigion, proportional to quadratic of thickness.