Published: 1939 Received: -Available on J-STAGE: November 27, 2008Accepted: September 07, 1939
Advance online publication: -
Revised: -
Correction information
Date of correction: November 27, 2008Reason for correction: -Correction: DTRECEIVEDDetails: Wrong : 19390907
Date of correction: November 27, 2008Reason for correction: -Correction: ABSTRACTDetails: Wrong : The Drying of bagasse is necessary not only from the view of heateconomy, but also of transmission. This report shows the calculation of the basic-figures necessary for drying bagasse from 30% water containt to 10% water containt with the aid of waste-gas from the boiler. The results are the following:- 1. Temp. of the drying gas (inlet) 240°C Temp. of the drying gas (outlet) 100°C 2. Water-evaporation per 1 hr 43.2 kg-mol. 3. D×L of dryer 2m× 6m 4. Quantity of the gas for drying per 1 hr 360kg-mol. 5. Velocity of drying gas 72m/min. 6. Issue-quantity of bagasse drying per 1hr 2720kg (containing 10% water) 7. Etc.
Date of correction: November 27, 2008Reason for correction: -Correction: PDF FILEDetails: -