Host: Japan Society for Fuzzy Theory and Intelligent Informatics (SOFT)
Galvanic Vestibular Stimulation (GVS) is known as a method of giving influence on sense of equilibrium. The vestibular system is stimulated by a weak current through an electrode placed on the mastoid behind the ear. In this paper, we had a motion guidance experiment of walking and the standstill operation by using GVS to evaluate the effect. And we measured the amount of the motion guidance with a motion capture system. We propose a motion guidance model to the change in a fixed fuel spray travel, time, the walking speed and compared it with the experiment result.