Simplified Machine Diagnosis Techniques Under Impact Vibration using n-th Moment of Absolute Deterioration Factor
*Kazuhiro TAKEYASU
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

Among many dimensional and dimensionless amplitude parameters, Kurtosis (4-th normalized moment of probability density function) is generally regarded as a sensitive good parameter for machine diagnosis. However, higher order moment may be supposed to be much more sensitive. Bicoherence is an absolute deterioration factor whose range is 1 to 0. The theoretical value of n-th moment divided by n-th moment calculated by measured data would behave in the same way. We propose a simplified calculation method for an absolute index of n-th moment and name this as simplified absolute index of n-th moment. The case in which the rolling elements number is nine is examined. Some favorable results are obtained.