USEFULNESS OF PORTABLE ULTRATHIN ENDOSCOPY THROUGH THE PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TUBE (PART 1)
Satoru ADACHI
Author information
JOURNAL FREE ACCESS

2011 Volume 53 Issue 6 Pages 1640-1645

Details
Abstract
Purpose : Percutaneous endoscopic gastrostomy (PEG) is widely used. However, there are concerns with adverse effects caused by improper PEG tube replacement. The usefulness of a portable ultrathin endoscope through the PEG tube was evaluated. Method : Ten outpatients (males 7, females 3 ; mean age of 61 years), who were treated with PEG tube feeding, were examined with the portable ultrathin endoscope. The tube sizes used included 20 to 24 Fr (Bumper-Button type). After an air injection adaptor (FUJI systems Co., Tokyo, japan) was connected to the PEG tube, the portable ultrathin endoscope (portable multiscope FP-7RBS2, PENTAX, Tokyo, Japan) was inserted into the tubes and observations were performed in the stomach. Result : In all the patients, it was easily recognizable that the PEG tube and internal bumper were in the stomach. There were no complications caused by this examination. Conclusion : This examination using the portable ultrathin endoscope may be useful in patients requiring PEG tube replacement. It can be easily and safely performed even at the bedside.
Content from these authors
© 2011 Japan Gastroenterological Endoscopy Society
Previous article Next article
feedback