GASTROENTEROLOGICAL ENDOSCOPY
Online ISSN : 1884-5738
Print ISSN : 0387-1207
ISSN-L : 0387-1207
THE CLINICAL EVALUATION OF THE UPPER G-I ENDOSCOPY WITH SMALL CALIBER FIBERSCOPE FGI-X1 (MACHIDA)
-Through the 2nd screening of gastric mass-servey-
SUSUMU KAWAMURAYUJI NAGATOMIMASAO KAWASHIMANOBUYUKI INUDOTETSUO MORIMOTOKAZUO HARIMAYOSHIO OSHITATAKASHI HARIMAKIYOSHI FUJITANOBORU MAETANIMITSUO AZUMASAKAE AOYAMAKIYOHIRO KAWAHARAMAKIZO HIRATAMASATOSHI WATANABENOBUHIRO SAKAKIMITSURU ODAWARAMICHIHIKO SHIMIZUTADASHI FUJIMASATOSHI MORITOYOSHIYUKI HAMADAYOZO IIDAYUKINORI OKZAKITADAYOSHI TAKEMOTO
Author information
JOURNAL FREE ACCESS

1979 Volume 21 Issue 5 Pages 548-555

Details
Abstract
Recently, the various type of pan-endoscope are made for several purposes. About pan-endos-cope which can observe from the esophagus to the bulbous portion, small caliber type seems to be sufficient. particularly for the routine examination and the 2nd screening examination of gastric mass-servey.In 100 cases that was required the 2nd screening of upper G-I tract in mass-servey, the endoscopy using the small caliber fiberscope FGI-X1 (Machida) was done easily and less pain-fully as well as using the small caliber f iberscope GIF-P2 (Olympus). As a conclusion, this FGI-X1 type pan-endoscope was very sufficient for the 2nd screening of gastric mass-servey. Specifications of this f iberscope are as follows: forward field view, out diameter 9.5mm, angle of view field 75°, working length 1.045mm, bending angle up to 180° down to 90°, right and left 120°.
Content from these authors
© Japan Gastroenterological Endoscopy Society
Previous article Next article
feedback
Top