Grand Renewable Energy proceedings
Online ISSN : 2434-0871
Japan council for Renewable Energy(2018)
Conference information

PRECISE MICROEARTHQUAKE HYPOCENTER DETERMINATION BY USING DETONATION SHOTS IN WELLS
*Hideshi Kaieda
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 263-

Details
Abstract

Fractures in geothermal reservoirs can be located in three dimension by the microearthquakes observation as their hypocenter locations. However, microearthquake hypocenter location accuracy is depended on the underground seismic wave velocity structure which has a strong heterogeneity in the geothermal areas. Calibration tests using detonation shots in deep wells can compensate the heterogeneity. Field tests conducted in the Ogachi Hot Dry Rock (HDR) experiment showed that artificially created fractures were located accurately with 10 to 20 m errors by station correction values which were obtained by calibration tests at about 1,070 m depth.

Content from these authors
© 2018 Japan Council for Renewable Energy (JCRE)
Previous article Next article
feedback
Top