Journal of the Geothermal Research Society of Japan
Online ISSN : 1883-5775
Print ISSN : 0388-6735
ISSN-L : 0388-6735
Temperature in a Test Pit Measured by Optical Fiber and a Laser
Yoshiteru SATOTakashi NARITATsuyoshi ISHIDAYoshiaki MIZUTAMichio KURIYAGAWAOsamu SAKAIHiroshi MARU
Author information
JOURNAL FREE ACCESS

1994 Volume 16 Issue 2 Pages 173-183

Details
Abstract
Temperature in a test pit of a metal mine was measured during a half month by a distributed temperature sensor. The sensor was optical fiber jacketed by a metal tube. The fiber bound along boring rods was inserted for 145m into the pit. Because of the metal jacket, the fiber sustained less damage by friction against rock around the pit. It stood also corrosion by hot water in the pit for a half month. The measured temperature was biased from the true one because the optical character of the fiber was different from that of the reference fiber constructed in the measuring system. In addition, owing to heat conduction along the fiber, temperature of a hot spot like inflow of hot water into a borehole was affected by temperature in surroundings. In spite of these errors, continuous measurement of temperature distribution by optical fiber helped us to understand the condition in the pit. It showed the change of flow rate in the pit and the difference of geological features of rock surrounding it.