Journal of High Pressure Institute of Japan
Online ISSN : 1347-9598
Print ISSN : 0387-0154
ISSN-L : 0387-0154
Explosive plugging method and performance test of plugging part
Seiichi KAGAKousuke SAKUMASeiji HIBIHiroyoshi MORIMOTOYoshiaki YAMAMOTO
Author information
JOURNAL FREE ACCESS

1985 Volume 23 Issue 6 Pages 320-331

Details
Abstract
If leakage are found on the heat exchanger tube in a super heater and an evaporater by the in-service inspection, and they are found to be unsuitable for further service, we must apply the plug in that tube and keep effectiveness of the plant.
We have two methods to plug in the heat exchanger tube. One is a welding process, the other is a explosive bonding. These methods are performed in meny plants including atomic power plant. But it is questionable to plug in the heat exchanger tube in the steam generetor of fast breader reactor plant which is heated by liquid sodium. Quality of post plugging heat treatment is very important factor to the reservice of the steam generetor.
So we demand the plugging method without heat treatment. This desirable method is explosive plugging.
To apply this method to the“Monju”, we must reserch meny patents and meny experiences of other plants, and we must develop original techniques.
Content from these authors
© High Pressure Institute of Japan
Previous article Next article
feedback
Top