Eddy-Current Testing of Nuclear Fuel Cladding Tubes Using Tilted Encircling Coil System
Ist Report, Basic Characteristics of Defect Signals
Renzhong YINKazuyoshi SEKINEHisaji SHIMIZUKazushige TSUKUIMegumu URATA
Author information
JOURNAL FREE ACCESS

1989 Volume 27 Issue 3 Pages 140-149

Details
Abstract
The eddy current testing method with external encircling-coils has been widely used as a standard technique for inspection of defects in irradiated zircaloy cladding tubes. In this inspection, the systematic procedure to reliably characterize defects is required.
This paper describes the newly developed external tilted encircling-coil system, in which the coil axis is inclined by an angle α to the sample tube axis, for reliable determination of the sort, location and size of defects. As the results of experimental work concerning some kinds of artificial defects in zircaloy cladding tubes using newly designed tilted coil system, an adaptable general-procedure for characterization of defects has been proposed. Furthermore, it has been confirmed that in the case of smaller tilt angles of coil, the signal-to noise ratio for defect response in this coil system is approximately equal to that of ordinary encircling coil system.