Abstract
The progress of digital audio technology enabled the familiar use of the products such as CD and DAT in the acoustic measurement. For example, a signal reproduced with CD player is inputted into a subject of measurement and DAT recorder records its response. However, the sampling cannot be synchronized completely with the input signal although both nominal sample rates are set up equally, because player and recorder work independently. It is the most popular software solution to perform the synchronous addition after converting the recorded signal into the original sampling rate. However, the rate conversion also has the error due to the windowing in the high frequency region of processed signal. This paper proposes a new method for averaging asynchronous sampling data to solve these problems. To evaluate performance, the transfer function of only measuring equipment estimated from asynchronous sampling data was compared with the measuring result in synchronous sampling condition. Both results agreed within 0.1dB, so the effectiveness of new method was confirmed. In measuring the frequency response of BPF under injecting white noise, the proposed method was compared with the method using rate conversion. As a result, the noise reduction was almost the same, and the processing time was reduced to about 1/4.