IEEJ Transactions on Electronics, Information and Systems
Online ISSN : 1348-8155
Print ISSN : 0385-4221
ISSN-L : 0385-4221
Tissue Extraction of Ultrasonic Image by Using Two-Dimensional AR Model
Atsushi TakemuraMasayasu Ito
Author information
JOURNAL FREE ACCESS

1995 Volume 115 Issue 12 Pages 1444-1451

Details
Abstract
An image obtained by ultrasonic medical equipment is poor in quality because of speckle noise, that is caused by the quality of ultrasonic beam and so on. Thus, it is very difficult to detect internal organs or the diseased tissues from a medical ultrasonic image by the processing, which is used only gray-scale of the image. To analyze the ultrasonic image, it is necessary to use not only gray-scale but also appropriate statistical character. In this paper, we suggest a new method to extract regions of internal organs from an ultrasonic image by the discrimination function. The discrimination function is based on gray-scale and statistical characters of the image. This function is determined by using parameters of the multi-dimensional autoregressive model.
Content from these authors
© The Institute of Electrical Engineers of Japan
Previous article Next article
feedback
Top