This paper presents a designing method of a robust controller which can be reduced within a prescribed degradation of a control performance. The method uses p-synthesis to take each variation of a plant and a controller into account. A numerical example is presented and its result is analyzed by using the Gap Metric.
A member of IEEJ can access the transactions of the Technical Society to which the member belongs. Please enter the My Page login ID in the subscriber number column and the birth date (year/month/date with one-byte characters: for example, 19800303) in the password column.