International Journal of Automation Technology
Online ISSN : 1883-8022
Print ISSN : 1881-7629
ISSN-L : 1881-7629
Special Issue on Laser Metrology for Precision Measurement and Inspection in Industry
Calibrator for 2D Grid Plate Using Imaging Coordinate Measuring Machine with Laser Interferometers
Mariko KajimaTsukasa WatanabeMakoto AbeToshiyuki Takatsuji
Author information
JOURNAL OPEN ACCESS

2015 Volume 9 Issue 5 Pages 541-545

Details
Abstract

A calibrator for 2D grid plates have been developed. The calibrator was based on a commercial imaging coordinate measuring machine (imaging CMM). A laser interferometer for the calibration of the x-coordinate and two laser interferometers for the calibration of the y-coordinate were attached to the imaging CMM. By applying multistep measurement method for the calibration procedure, the geometrical error in the calibrator was reduced. The calibration of a precision 2D grid plate was demonstrated, and the expanded uncertainty was estimated to be 0.2 μm (k=2).

Content from these authors

This article cannot obtain the latest cited-by information.

© 2015 Fuji Technology Press Ltd.

This article is licensed under a Creative Commons [Attribution-NoDerivatives 4.0 International] license (https://creativecommons.org/licenses/by-nd/4.0/).
The journal is fully Open Access under Creative Commons licenses and all articles are free to access at IJAT Official Site.
https://www.fujipress.jp/ijat/au-about/