Employing rotating vaneless diffuser to enhance the performance of plenum fan
Hua-Shu DouLin WuYikun WeiYongning ChenWenbin CaoCunlie Ying
Author information
JOURNAL FREE ACCESS

2017 Volume 10 Issue 1 Pages 9-18

Details
Abstract

Numerical simulation is carried out for flow characteristics in a plenum fan and the influence of the diameter ratio of the rotating vaneless diffuser on the performance of plenum fan is analyzed. The diameter ratio of the rotating vaneless diffuser employed is from 1.03 to 1.3. The research results show that the rotating vaneless diffuser is able to enhance the performance of plenum fan. It is found that there is significant improvement in static pressure and efficiency at the diameter ratio of 1.05 at high flow coefficients, while the optimal diameter ratio is 1.2 at rated and low flow coefficient.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2017 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
Previous article Next article