International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
Original papers
Cavitation Compliance in 1D Part-load Vortex Models
Peter K Dörfler
Author information
JOURNAL FREE ACCESS

2017 Volume 10 Issue 3 Pages 197-208

Details
Abstract

When Francis turbines operate at partial load, residual swirl in the draft tube causes low-frequency pulsation of pressure and power output. Scale effects and system response may bias the prediction of prototype behavior based on laboratory tests, but could be overcome by means of a 1D analytical model. This paper deals with the two most important features of such a model, the compliance and the source of excitation. In a distributed-parameter version, compliance should be represented as an exponential function of local pressure. Lack of similarity due to different Froude number can thus be compensated. The normally unknown gas content in the vortex cavity has significant influence on the pulsation, and should therefore be measured and considered as a test parameter.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2017 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
Previous article Next article