Abstract
This paper presents control system synthesis of providing a balance between normal-case performance, safety and fault-case performance according to the international standard on safety, IEC 61508. It is based on multiobjective design for simultaneous problems for each context to optimize only normal-case performance out of the whole including fault-case performance.