1996 Volume 1996 Issue 3 Pages 585-590
In this paper a K-type fluid filter is theoretically studied. the impedance matching theorem and this filter model of hydraulic system are put forward. A lot of experimental work is done for finding out the optimal value of filter parameters. For a well designed filter, 85% pressure fluctuation after filter and its 60% before filter can be filtrated.