ISIJ International
Online ISSN : 1347-5460
Print ISSN : 0915-1559
ISSN-L : 0915-1559
Regular Article
Microstructural Evaluation and Ultrasonic Characterization of TLPD bonded 6061-SiCp Composite
Joydeep MaityTapan Kumar PalRabindranath Maiti
Author information
JOURNAL FREE ACCESS

2008 Volume 48 Issue 5 Pages 616-623

Details
Abstract

Microstructural evaluation during transient liquid phase diffusion (TLPD) bonding of extruded aluminium based metal matrix composite (6061-15 wt% SiCP) using 50 μm thick copper interlayer was investigated by optical microscopy, scanning electron microscopy (SEM) together with SEM-based energy dispersive X-ray spectroscopy (EDS) and pulse echo ultrasonic test. Microstructural changes in the joint region were examined at five different holding time (20 min, 1 h, 2 h, 3 h and 6 h) for a bonding temperature of 560°C under two different applied pressures (0.1 MPa and 0.2 MPa). Kinetics of the bonding process was significantly accelerated in presence of reinforcement (SiC). This acceleration is attributed to the increased solute diffusivity through defect-rich SiC particle/matrix interface and porosity. The segregated particle at bond interface caused significant attenuation of ultrasonic wave, especially at lower bonding time. The attenuation effect decreased with increasing bonding time as width of particle segregation decreased.

Content from these authors
© 2008 by The Iron and Steel Institute of Japan
Previous article Next article