ISIJ International
Online ISSN : 1347-5460
Print ISSN : 0915-1559
ISSN-L : 0915-1559
Regular Article
Three-dimensional Observation of Nonmetallic Inclusion Clusters in Solid Metal by X-ray Micro-CT
Tao Li Shin–ichi ShimasakiShoji TaniguchiShunsuke NaritaKentaro Uesugi
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML

2016 Volume 56 Issue 11 Pages 1989-1995

Details
Abstract

In this study, we developed a method of observing three-dimensional (3D) inclusion clusters in metal. The theory of X-ray micro-computed tomography (CT) is generally introduced. The criteria on determining the sample size and energy of X-ray beam is set according to the characteristics of the beamline BL20XU available at Spring-8, which is the largest synchrotron radiation facility. The Al–TiB2 and Al–SiC system were measured by the X-ray micro-CT available in beamline BL20XU at Spring-8. The determination of the sample size the energy of X-ray beam are discussed on basis of the X-ray linear attenuation coefficient (LAC) and the transmission rate of Al–TiB2 and Al–SiC system. The limitation of the charge coupled device (CCD) camera, such as spatial resolution and observing field, are taken into consideration as well. Phase retrieval method is applied to reduce the noises of tomographic images for Al–SiC system due to its poor contrast. The 3D particle clusters of TiB2 and SiC are reconstructed by self-developed program. The fractal dimension of TiB2 and SiC clusters are calculated around 2.7. The feasibility of observing alumina cluster in steel is discussed on basis of the latest capability of beamline BL20XU at Spring-8.

1. Introduction

The inclusions in metal products largely decrease their mechanical properties. The fine inclusion particles coagulate each other in molten metal and grow up to clusters, which are much more harmful. It is an everlasting topic to remove inclusions as much as possible and control morphology of the remaining inclusions in metal products.

The three-dimensional (3D) structure of inclusion clusters plays a key role in the inclusion behaviors in molten metal. The 3D analysis of the inclusion cluster structure will provide significant information for understanding the mechanisms of inclusion behaviors in liquid metal, such as inclusion coagulation, flotation and bubble adhesion. Many modelling and experimental works1,2,3,4,5) have been performed to investigate the inclusion behaviors by using spherical particles. Nevertheless, the morphology of the inclusions is far from spherical when they coagulate each other and grow up into clusters.

Fractal dimension6,7) is one of the most important parameters describing the morphology of particle clusters, which specifies the relationship between the volume (area) and the size in length of a cluster. It is currently most common to observe of the inclusions on two-dimensional (2D) cross-sections of a sample from metal products. An inclusion cluster appears as a few of isolated particles on a 2D cross-sections of the samples. Tozawa et al.8) firstly investigated the fractal dimension of alumina cluster in steel sample and its influence on floating velocity of clusters in liquid. The fractal dimension of an alumina cluster was calculated by 2D measurement of the cross-sections of a steel sample, which yielded a fractal dimension of 1.8. The model of cluster flotation velocity in liquid was modified using fractal dimension; it agreed well with the cold model experiments. Doo et al.9) investigated the fractal dimension of the alumina cluster extracted from steel according to the projected area of the cluster. The 2D fractal dimension was reported in the range of 1.80–1.95 with average of 1.88.

However, those works above are all on basis on the observation on 2D cross section or projection area. It is very rare to find the experimental reports about 3D cluster structure analysis, especially the nonmetallic particle clusters in metal system because of its opaque and high melting point. X-ray Micro-CT is recently applied to observe the 3D pores and cracks in metal and polymer,10,11) which is well known as nondestructive inspection method.12,13,14,15) To achieve the 3D observation, the contrast of between the materials in the samples should be detectable, which is determined by the sample size, X-ray power and the types of materials. Mostly, the pores and crack in the solid have quite enough contrast of X-ray absorption rate to the solid material, particularly in polymers. It would be difficult to obtain an enough X-ray transmission rate for observation of metal samples. Hamilton et al.16) made an effort to observe the TiB2 particles by X-ray micro-CT. However, the resolution is only 5 μm, which is not sufficient to derive quantitative description of the 3D morphology of the TiB2 particles.

A beamline of X-ray micro-CT is available in Spring-8, which is a large synchrotron radiation facility available in Japan. It yield a resolution of 0.5 μm, which is ten time higher than Hamilton’s work.16) The current authors’ group has applied the X-ray micro-CT to study the 3D structure of TiB2 and SiC particle clusters in aluminium.17,18) The coagulation of SiC particles in molten aluminum was studied based on the 3D observation of the particle clusters,5) which attracted quite a lot interests from researchers. In this study, we disclose the details of the development of the 3D observation method for Al–TiB2 and Al–SiC systems. The sample size and energy of X-ray source are determined by calculating the X-ray attenuation efficiencies and the transmission rate of the samples. This study opens an eye to observe and measure the morphology of inclusion clusters in metal product. The feasibility of observing alumina clusters in steel is discussed as well.

2. Experimental

The samples of aluminium with particle clusters were prepared in the mechanical agitating crucible,5,17,18) which contains molten Al and particles (TiB2 or SiC). The molten aluminium with particles was stirred in a crucible at 973 K to prepare the particle clusters in aluminium. The size of the TiB2 particle varies from 2–30 μm with peak diameter at 20 μm. The volume fraction of the particle is around 0.5 vol%. While the size of SiC particles is in the range of 2–30 μm with peak diameter at 12 μm. The volume fraction of SiC is up to 2 vol%.The samples were sucked from the molten aluminium by the silica tube with diameter of 3 mm, and then processed by electron discharge machining to fit the requirement of the X-ray micro-CT.

Figure 1 shows the photo of the micro-CT in beamline BL20XU at Spring-8 and the processed sample. It is difficult to obtain a sample with diameter less than 0.5 mm by the electron discharge machining. On the other hand, the size of the charge coupled device (CCD) camera in the beamline of BL20XU is 0.95 mm in width and 0.7 mm in height. Therefore, the maximum diameter of the sample should be less than 0.95 mm in diameter. The sample size is set in the range of 0.5 mm–0.8 mm in this study; and the details of determining the sample size is discussed below.

Fig. 1.

Micro-CT in beamline BL20XU at Spring-8.

3. X-ray Tomography

3.1. BL20XU at Spring-8

Spring-8 is a large synchrotron radiation facility that delivers the most powerful synchrotron radiation available in Japan. The beamline BL20XU is designed to the imaging technologies, which is the second medium-length beamline in the Spring-8. Monochromator in beamline BL20XU is “Spring-8 standard” double crystal monochromator. The first crystal of monochromator is combination of Si (111) orientation crystal and Si (511) orientation. These two crystals are interchangeable by using linear-translation stage without venting the monochromator vacuum. The second crystal is Si 111–orientation. The energy region of X-ray beam was 8–37 keV before and recently extended into 7.62–113 keV.

Figure 2 shows the principle of X-ray micro-CT. The parallel X-ray beam from source penetrates the sample and is partly absorbed by the sample; the charge–coupled device (CCD) camera detects the received energy of X-ray and generates projection images. The raw data for the sample are composted by multiple projections of the object being scanned. Tomographic reconstruction, essentially involves solving the inverse Radon transformation,19) produces a series of cross-sectionsal images.

Fig. 2.

Principle of X-ray micro-CT.

3.2. X-ray Attenuation

The contrast of the materials in the micro-CT images is determined by the X-ray linear attenuation rate of the different materials. The exponential attenuation law of a narrow beam of monoenergetic photons (X–ray) with an incident intensity I0, penetrating a layer of sample is given by   

I I 0 =exp[ - μ m x ] (1)
where, I is the intensity of X-ray penetrating the sample, x is the mass thickness of the sample and μm is the X-ray mass attenuation coefficient (MAC).

The X-ray MAC μm is expressed by the X-ray linear attenuation coefficient (LAC) μl,   

μ m = μ l /ρ (2)
Where, ρ is the density of material in the sample.

The mass thickness x is defined as the mass per unit area, which is obtained by product of the material density and the thickness L in length,   

x=ρL (3)

By combining Eqs. (1), (2), (3), the X-ray transmission rate is given by   

I I 0 =exp( - μ l L ) (4)

The attenuation law mentioned above is based on the system including one type of materials. The X-ray contrast of two different materials is estimated by the relative difference in linear attenuation.   

Difference= | μ l,1 - μ l,2 | μ l,1 (5)
where, component–1 is dominated in the mixture. It is possible to distinguish the difference of materials when the relative difference in LAC exceeds 20%.

The volume fraction of each material should be taken into account in a multiple materials system. The X-ray transmission rate of a multiple material is expressed by   

I I 0 =exp[ - i n φ i μ l,i L ] (6)
where, φi is the volume fraction of the component–i.

To determine the size of samples and the energy of X-ray beam, the following criteria should be considered.

(1) Due to the small size of TiB2 and SiC particles, the spatial resolution of the CCD camera should be less than 1 μm. The maximum observing field then is 0.95 mm in width and 0.7 mm in height, which is limited by the CCD camera. Thus, the maximum diameter of the sample is set as 0.8 mm for safety.

(2) The X-ray energy available at BL20XU is between 8–37 keV when the sample of Al–TiB2 and Al–SiC were measured.

(3) The acceptable X-ray transmission rate is in the range is 0.2–0.8, with optimist value around 0.5.

(4) For the sake of involving more particle clusters in the sample, the sample volume should be as much as possible, on the premise of enough X-ray transmission rate and contrast in the X-ray micro-CT images.

3.3. Micro-CT Image Reconstruction

The sample was settled between the X-ray source beam and the CCD camera. Numbers of projection images were taken by the CCD camera when the sample is rotating with a constant angular speed. In this study, totally 1891 projection images were taken for each sample of Al–TiB2, in which the first 1–60 images are for background, 61–1860 for the rotating samples (10 shots/degree), and 1861–1891 for background again. For the Al–SiC system, the projection number was set as 3691 to deduce the noise, in which 1–60 are for background, 61–3660 are the projections for samples, and 3661–3691 are for background again to confirm (180 degree, 20 shots/degree).

The projection images were then transferred into cross-sectionsal images of the sample. The spatial resolution of the CCD camera is 0.5 μm. Totally, 1439 slices were obtained for each sample with the observed length of around 0.715 mm, which is limited by the CCD camera. ImageJ was applied to process the 16 bit Micro-CT images, which is a public domain image processing software built up by the National Institutes of Health. A self-developed program developed on ImageJ to extract 3D clusters from the micro-CT image stacks, which was explained in detail in our previous work.17)

4. Results and Discussions

4.1. Measurement of Aluminium Containing Particles

The X-ray MAC is a function of the atomic number of the elements included in the materials. The atomic number of main elements in metal matrix and particles are listed in Table 1. The atomic numbers of C and B are quite closed. However, the Si in SiC is adjacent to Al; while the Ti in TiB2 has large difference from Al in the atomic number that would lead to a much larger contrast between aluminium and TiB2.

Table 1. Atomic number of main elements in metal matrix and particles.
MaterialDensity (g/cm3)ElementAtomic NumberAtomic Weight
Metal matrix2.7Al1327
SiC particle3.21Si1428
C612
TiB2 particle4.52Ti2248
B511

Figure 3 shows the X-ray MAC of Al matrix and particles (TiB2 and SiC).20) The gap between Al matrix and TiB2 particle in X-ray MAC is quite large; while the difference of that between Al matrix and SiC is very small, particularly with increasing energy of X-ray beam.

Fig. 3.

X-ray MAC of Al matrix and particles (TiB2 and SiC).

The X-ray transmission rate is a function of the LAC and the size of the sample. Figure 4 shows the X-ray LAC of Al matrix and TiB2 particles and their relative difference. The X-ray LAC show the same tendency to the X-ray MAC. The difference of the LAC between Al and TiB2 is far greater than the criteria of 20% in the entire X-ray energy range of from 8 keV up to 37 keV, though it decreases at 20 keV of X-ray energy beam. Due to the large difference in LAC between Al and TiB2, the problem of contrast could be emitted from the consideration. The transmission rate is then the key factor on determining the energy of X-ray beam and the sample size of Al–TiB2.

Fig. 4.

X-ray LAC of Al matrix and TiB2 particles and their difference.

Figure 5 shows the X-ray transmission rate for Al–TiB2, which is calculated by Eq. (6) with varying sample sizes. Since the volume fraction of TiB2 particles in the sample is very small, it has little effects on the X-ray transmission rate. It is acceptable to observe the samples with an X-ray transmission rate of 0.2–0.8, with optimized value at 0.5 for the observation. In order to increase the particle clusters containing in the observed sample, the sample size is determined at the maximum (0.8 mm), which is limited by the CCD camera. The energy of X-ray beam is around 20 keV to achieve the transmission rate of 0.5; and was finally fixed at 19.99 keV after testing the quality of the X-ray images.

Fig. 5.

X-ray transmission rate of Al–TiB2 (0.5 vol% TiB2).

Figure 6 shows the change of LAC of Al and SiC with X-ray energy. It is obvious that the difference in LAC between Al and SiC is much smaller than that between Al and TiB2. The SiC particles may be difficult to be distinguished by the CCD camera in the X-ray micro-CT images. Figure 7 shows the X-ray transmission rate of Al–SiC containing 2 vol% particles. The X-ray transmission rate of the sample with certain size increases with the increasing energy of X-ray beam; whereas it decreases with the increasing size of samples exposed under the X-ray with the same energy. It turns out that, on basis of Fig. 6, the contrast between Al and SiC increases with X-ray energy. On the other hand, it is required to adjust the X-ray transmission rate to be around 0.5 in order to achieve the best contrast of micro-CT image. When the sample size is set at 0.8 mm in diameter, the energy of X-ray beam should be around 21 keV according to Fig. 7. However, the thicker the sample, the more noise comes from photon scattering, which would practically decrease the contrast. In this way, a thinner sample should be used for Al–SiC system. The sample size of Al–SiC is set at 0.5 mm in diameter and the energy of the X-ray source is set as 18 keV to obtain an X-ray transmission rate of 0.50.

Fig. 6.

X-ray LAC of Al matrix and SiC particles and their difference.

Fig. 7.

X-ray transmission rate of Al–SiC (2 vol% SiC).

4.2. 3D Reconstruction of Particle Clusters in Aluminium

An example of 8-bit micro-CT cross-sectional image of Al–TiB2 sample is show in Fig. 8(a). The white area is TiB2 particles; the grey area is Al matrix; and the black area is the background of air. It turns out that the contrast between Al and TiB2 is quite large. Figure 8(b) shows the binary image preprocessed image by setting a threshold of grey value in ImageJ.

Fig. 8.

Cross-sectional image from X-ray Micro-CT and processed image.

The particle clusters in the samples are reconstructed from the series of cross-sectional images by a self-developed program based on ImageJ. Figure 9 shows an example of TiB2 clusters and its cross-sectional slices. It is obviously difficult to identify the cluster when one of the slices appears independently. The fractal dimension of the cluster is 2.74, which is calculated by   

V= π 6 d ave D f (7)
where, the V is the volume of the cluster; dave is the average diameter of the cluster in x, y and z direction; Df is the fractal dimension.
Fig. 9.

Example of TiB2 cluster and its cross sectional slices.

When it comes to the Al–SiC system, the contrast of the X-ray micro-CT images becomes poor. Figure 10(a) shows an 8-bit micro-CT image of Al–SiC sample. A magnified area is shown in Fig. 10(b) where the fine dots in the Al matrix have the similar grey values as the SiC particles. It is difficult to identify the SiC particle from the Al matrix e by setting a threshold of grey value, as done for Al–TiB2.

Fig. 10.

X-ray micro-CT image obtained by ordinary reconstruction method.

The quality of the tomographic images were largely improved by applying the phase retrieval methods21,22,23) implemented by Transport-of-Intensity equation22) using fast Fourier transform (FFT) method.23) The phase-retrieval method was developed to obtain the projected phase and absorption information of the object in multi-material objects with distinct complex refractive indexes. The algorithm was implemented using phase contrast data acquired at the Spring-8 Synchrotron facility in Japan. The 3D complex refractive index distribution of a multi-material test object was quantitatively reconstructed using a single X-ray phase contrast image per projection. The technique is robust in the presence of noise, compared to conventional absorption based tomography. Figure 11(a) shows a normalized X-ray micro-CT image of Al–SiC obtained by the phase retrieval based on FFT algorithm. As seen from Fig. 11(b), the noise of dots shown in Fig. 10 has been largely removed. The phase retrieval images are then and converted into 8-bit images; and a threshold is set to convert the images into binary, which are shown in Fig. 12. Figure 13 gives an example of SiC cluster whose fractal dimension is 2.7 calculated by Eq. (7). It shows a similar contracture as TiB2 clusters. On basis of statistical analysis of thousands of TiB217) and SiC5) clusters, it turned out that their fractal dimension is around 2.7. The fractal dimension of the 2D cross-sectional particles is around 1.8, which agreed well with Tozawa’s work for alumina cluster in steel.8)

Fig. 11.

Normalized X-ray micro-CT image obtained by phase retrieval.

Fig. 12.

X-ray micro-CT images processed by ImageJ.

Fig. 13.

Example of SiC cluster and its cross sectional slices.

4.3. Alumina Cluster in Steel

The atomic number of Fe (26) is much larger than that of Al; thus it would be much difficult for the X-ray to penetrate the steel sample. It thus requires a much higher energy of X-ray to observe the steel sample than that for aluminium samples. Figure 14 shows the LAC of Fe and Al2O3 and their relative difference. An energy absorption edge25) appears at 9 keV for Fe, due to the photoelectric effect, which is caused by the removing of electrons from the shells around the nuclear in the atoms. It is common to set the energy of X-ray beam around the absorption edge, which results in the maximum contrast of the micro-CT image. However, the X-ray transmission rate of the sample is another critical factor of observation. Figure 15 shows the X-ray transmission rate for Fe–Al2O3 samples containing 1 vol% Al2O3. The volume fraction is calculated by assuming that all the inclusions in the steel sample (T[O] = 20 ppm) appearing in term of Al2O3. The X-ray transmission rate is extremely small with photon energy of 9 keV, though the contrast between Fe and Al2O3 is large. Actually, the minimum X-ray energy is around 30 keV even for observing a sample with diameter of 200 μm. Figure 16 shows an alumina cluster extracted from a steel sample.9) The size of alumina clusters reaches several tens microns, even a hundred microns. Therefore, it is difficult to guarantee that alumina clusters are involved in a sample with diameter of 0.2 mm. Fortunately, the energy range of X-ray up to 113 keV is currently available at beamline BL20XU at Spring-8, which makes it possible to observer Fe–Al2O3 samples with larger size. On the other hand, the spatial resolution should be less than 1 μm due to the small size of alumina particles contained in the cluster. We set the maximum diameter of the sample at 0.8 mm as before due to the limitation of the observing field of the CCD camera. Therefore, the energy of X-ray beam should be around 60 keV for to achieve an X-ray transmission rate around 0.5. The measurable sample size would theoretically reach to 3 mm if a CCD camera with enough spatial resolution is available.

Fig. 14.

X-ray LAC of Fe and Al2O3 particles and their relative difference.

Fig. 15.

X-ray transmission rate of Fe–Al2O3 (1 vol% Al2O3).

Fig. 16.

Alumina extracted from steel sample.

Though the behavior of alumina inclusions has been attracting much interest, the other types of inclusion have bad influence to the steel products as well. The feasibility of 3D observation of other inclusion would be considered in the future. The contrast is low when the elements in the inclusions have similar atomic number to Fe, such as FeO, MnO, and MnS. The phase retrieval method would then be applied as done for Al–SiC system.

5. Conclusions

In this study, the method of observing 3D inclusion clusters in metal was disclosed in details. The Al–TiB2 and Al–SiC system were measured by the X-ray micro-CT available at Spring-8. The 3D reconstruction of the X-ray micro-CT images was presented, with the calculation of the fractal dimension. The feasibility of observing alumina cluster in steel is discussed on basis of the latest capability of beamline BL20Xu at Spring-8.

(1) The contrast of Al–TiB2 system is sufficiently large that it does not effect on determining the sample size. The sample size is then limited by the observing field of the CCD camera. The energy of X-ray beam is set at 19.99 keV to achieve an X-ray transmission rate of 0.55.

(2) The difference in LAC between Al and SiC is pretty close that the contrast on the micro-CT images is bad. In order to reduce the noise coming from photon scattering, the sample size is set to be the minimum (0.5 mm) processable by electron discharge machining. And the energy of X-ray beam is set at 18 keV to achieve an X-ray transmission rate of 0.50.

(3) The X-ray micro-CT images of Al–TiB2 is easier to be processed due to its large contrast; while the phase retrieval method is applied to the tomographic images of Al–SiC to reduce the noises. The fractal dimension of both TiB2 and SiC clusters in aluminium is around 2.7.

(4) The alumina clusters in steel is theoretically able to be observed currently due to the larger range of X-ray energy available in beamline BL20XU at Spring-8. The sample should be processed into cylinder with diameter around 0.8 mm. The energy of X-ray should be around 60 keV.

Acknowledgement

This work was partly supported by Grant–in–Aid for Scientific Research (A) (No. 22246097) which is provided by Japan Society for the Promotion of Science (JSPS). Project numbers of Spring-8 are 2011B1395 and 2012B1448 on beamline BL20XU. The authors wish to express thanks to Dr. A. Takeuchi and Dr. Y. Suzuki for their help during the operation of the X-ray micro-CT at Spring-8. We also thanks Dr. M. Iguchi of Nihon Ceratec Co., Ltd. for the cooperation on preparing the Al–TiB2 metal matrix composite.

References
 
© 2016 by The Iron and Steel Institute of Japan
feedback
Top