Transactions of the Iron and Steel Institute of Japan
Online ISSN : 1881-1183
Print ISSN : 0021-1583
Factors Affecting the Accuracy of Plate Thickness and Their Influences on Plate Flatness
Katsuaki KOKAIYukihiro KAKOKoe NAKAJIMA
Author information
JOURNAL FREE ACCESS

1985 Volume 25 Issue 6 Pages 482-488

Details
Abstract

In plate rolling, the plate thickness is controlled by using the mill itself as a plate thickness measuring device, namely Gaugemeter. To maintain the Gaugemeter accuracy is very important not only for plate thickness control but also for plate flatness control. That is:
(1) The Gaugemeter error is a basic factor which impairs the accuracy of plate thickness.
(2) The Gaugemeter error sometimes reaches 1008μm.
(3) The variation in the plate thickness based on the Gaugemeter error can become the largest factor that affects badly plate flatness through the variation in the rolling load.