PROCEEDINGS OF THE ITE ANNUAL CONVENTION
Online ISSN : 2424-2292
Print ISSN : 1343-1846
ISSN-L : 1343-1846
2011
Session ID : 13-7
Conference information

13-7 Calculations of SAR in Human Body due to Transceiver for Push-to-Talk Communication Line in VHF Band
Naoto KOGOTetsuomi IKEDA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
The push-to-talk communication line for broadcasting organization is used in VHF band (160MHz Band), and used for a way of communication in the program production. In this report, we designed a helical antenna with a metal case as a handy-type transceiver and calculated the SAR in the human body exposed to electromagnetic waves from the antenna. As a result, the SAR in the human body exposed to electromagnetic waves from the antenna located as usual operation satisfied the limit value indicated in the safety guidelines by the ministry of internal affairs and communications.
Content from these authors
© 2011 The Institute of Image Information and Television Engineers
Previous article Next article
feedback
Top