Thermal Performance Test of Hot Gas Ducts of Hilium Engineering Demonstration Loop (HENDEL)
Makoto HISHIDAKazuhiko KUNITOMIIkuo IOKAKoji UMENISHIYasuo KONDOToshiyuki TANAKAHiroaki SHIMOMURA
Author information
JOURNAL FREE ACCESS

1984 Volume 26 Issue 6 Pages 506-518

Details
Abstract
A hot gas duct provided with internal thermal insulation is supposed to be used for an experimental very high-temperature gas-cooled reactor (VHTR) which has been developed by the Japan Atomic Energy Research Institute (JAERI). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of hot gas duct have been conducted. The present test was to investigate the thermal performance of the hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL) of JAERI.
Uniform temperature and heat flux distributions at the surface of the duct were observed, the experimental correlation being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of VHTR hot gas duct was evaluated, and no hot spot was detected.
These results would be very valuable for the design and development of VHTR.