Journal of the Anus, Rectum and Colon
Online ISSN : 2432-3853
ISSN-L : 2432-3853
Clinical Research
Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study
Yorinari OchiaiHiroyuki OdagiriJunnosuke HayasakaTakayuki OkamuraYugo SuzukiYutaka MitsunagaKazuhiro FuchinoueMasami TanakaKosuke NomuraSatoshi YamashitaAkira MatsuiDaisuke KikuchiShu Hoteya
Author information
JOURNAL OPEN ACCESS
Supplementary material

2022 Volume 6 Issue 4 Pages 282-288

Details
Abstract

Objectives: Recently, a newly designed short-type single-balloon enteroscope (SBE), SIF-H290S, has been developed with a smaller outer diameter and a longer working length than conventional colonoscopes. It has passive bending and high-force transmission, making insertion easier. However, it is difficult to perform rescue colonoscopy with an SBE after incomplete colonoscopy in the same session. Therefore, this study evaluated the feasibility of consecutive rescue colonoscopy using SIF-H290S without overtube after incomplete colonoscopy.

Methods: This was a single-center retrospective study. We included 19 rescue colonoscopies (19 patients) with SIF-H290S without overtube performed by 11 endoscopists in the SIF group and 38 rescue colonoscopies (38 patients) using a small-caliber colonoscope (PCF-PQ260L) were randomly selected for the control group from procedures performed by the same 11 endoscopists. We compared the cecal intubation rate and other outcomes, such as insertion time, between the two groups.

Results: The median age of the patients was 72 and 69 years, with 8 and 26 males in the SIF and control groups, respectively. The median body mass index was 21.6 and 22.7 kg/m2 in the SIF and control groups, respectively. There were no significant differences in the patient backgrounds between the groups, except for the reason for incomplete colonoscopy (p = 0.048). The cecal intubation rate was 78.9% (15/19 procedures) and 92.1% (35/38 procedures) in the SIF and control groups, respectively.

Conclusions: This study revealed the real-world experience and feasibility of rescue colonoscopy using SIF-H290S, which could be a potential rescue device option after incomplete colonoscopy.

Fullsize Image
Content from these authors
© 2022 The Japan Society of Coloproctology

JARC is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. Anyone may download, reuse, copy, reprint, or distribute articles published in the Journal for non-profit purposes if they cite the original authors and source properly. If anyone remixes, transforms, or builds upon the material, you may not distribute the modified material.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article
feedback
Top