Summaries to Technical Papers of Annual Meeting, Japan Association for Wind Engineering
Annual Meeting 2017, Japan Association for Wind Engineering
Conference information

Proceedings of Anuual Meeting 2017
Development of rotation flow VAWT for pumping system
TAKASHI SHIDA*TAKESHI KUBOTA*AKIHIRO HONDA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 139-140

Details
Abstract

Wind tunnel tests of ‘Rotational Flow Wind Turbine’, 0.94 m in diameter, and 0.847m in height, was conducted. The turbine has eight blades, and two kinds of blade width was tested.

The torque coefficient at the tip speed ratio of 0.2 was above 0.25, and maximum power coefficient shows the value of 0.07 at the tip speed of 0.38.

Additionally, a vane-type hydraulic pump, which was directly connected to the wind turbine, was certificated to be able to pump up the water above 5.7m height.

Content from these authors
© 2017 Japan Association for Wind Engineering
Previous article Next article
feedback
Top