JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
Original Papers
Effect of Secondary Air Injection on Axial Solid Holdup Distribution in a Circulating Fluidized Bed
Yong Jun ChoWon NamkungSang Done KimSunwon Park
Author information
JOURNAL FREE ACCESS

1994 Volume 27 Issue 2 Pages 158-164

Details
Abstract
The effects of secondary air ratio (0–50%), height of injection port (1.5–2.5 m) and injection types (radial and tangential) on the axial solid holdup distribution have been determined in a circulating fluidized bed (0.1 m I.D. × 5.3 m high). As the secondary air ratio is increased, solid holdup increases below the secondary air port, whereas it decreases slightly above the secondary air injection port. The dense bed height increases with increasing height of the secondary air injection port. Different types of secondary air injection system do not produce any significant difference in the overall axial solid holdup distribution. However, solid holdup just above the injection port in a tangential secondary air injection system exhibits somewhat higher values than those of radial secondary air injection system. The effect of secondary air injection on the axial solid holdup distribution in a circulating fluidized bed can be predicted by a modified freeboard-entrainment model with decay constants determined from the proposed correlation.
Content from these authors
© 1994 The Society of Chemical Engineers, Japan