JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
Poor Fluidization Phenomena and Detection in the FBAC of the Tonghae CFB Boiler
Jong-Min LeeDong-Won KimJae-Sung KimJong-Jin Kim
Author information
JOURNAL RESTRICTED ACCESS

2008 Volume 41 Issue 7 Pages 710-715

Details
Abstract

Detection and clearance of poor fluidization in a simulated fluidized bed ash cooler were studied by analyzing the mixing properties of the bed materials and the pressure fluctuation of the air header distributor. We observed a bridge of large particles at the bed surface which caused the poor fluidization area to form at the entrance of the FBAC. The poor fluidization was caused not only by airflow rates but also by the particle discharge rates as well as particle size distribution in the FBAC. Additionally, we could easily detect the local poor fluidization through a simple method developed in the simulated FBAC and in the FBAC of the Tonghae CFB boiler. As local poor fluidization is detected, it should be possible to clear it up by regulating the flow rate of each air header in the FBAC.

Content from these authors
© 2008 The Society of Chemical Engineers, Japan