Ibuprofen Racemate Separation by Simulated Moving Bed
Joon Sup ParkWoo-Sik KimJong Min KimIn-Ho Kim
Author information
Keywords: SMB, Ibuprofen, Chiral
JOURNAL RESTRICTED ACCESS

2008 Volume 41 Issue 7 Pages 624-626

Details
Abstract

Ibuprofen racemates were separated in a SMB system with 4 chromatographic columns packed with TBB gels. Retention times of R- and S-enantiomers of ibuprofen were measured in batch chromatography experiments with hexane/TBME/acetic acid mixed solvent. Isotherm parameters of SMB were calculated from the batch chromatography data, and operation flow parameters obtained from m2 and m3 plane of Morbidelli and coworkers (Abel et al., 2004). Experimental results are summarized as purities of raffinate. In order to compare experiments with simulations, ASPEN Chromatography Simulator was adopted. Isotherm and operation parameters were inserted to the dialog box of the simulator and output display data was cropped for comparison of experiments and simulations.

Content from these authors
© 2008 The Society of Chemical Engineers, Japan