JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
EVALUATION OF THE ISOTOPE SEPARATION RATE OF DEUTERIUM EXCHANGE REACTION BETWEEN H2 AND H2O WITH PLATINUM CATALYST
ASASHI KITAMOTOYOICHI TAKASHIMAMASAMI SHIMIZU
Author information
JOURNAL FREE ACCESS

1983 Volume 16 Issue 6 Pages 495-502

Details
Abstract

The high performance catalysts of hydrophobic carrier with fully dispersed platinum were used to measure the isotope separation performance of hydrogen by the chemical exchange method. The continuous injection of oxygen on the order of 103ppm was effective in regenerating catalyst activity and in maintaining high performance for a long time.
The separation performance in a trickle bed column should be evaluated by using two parameters, K9 and Kl. These two parameters were unified to the overall transfer coefficient Kfg, which may be sufficient in the estimation of overall performance or the design of a separation plant by the chemical exchange method.
When one wants to increase the transfer rate in a chemical exchange column, the improvement of Kl rather than Kg may be more effective in increasing the overall transfer rate (its coefficient is expressed by Kfg in this paper).

Content from these authors
© The Society of Chemical Engineers, Japan
Previous article Next article