Journal of the Ceramic Association, Japan
Online ISSN : 1884-2119
Print ISSN : 0366-9998
ISSN-L : 0366-9998
Resistance of Glass plate to the Wind pressure
Naojiro Matsuo
Author information
JOURNAL FREE ACCESS

1933 Volume 41 Issue 484 Pages 188-199

Details
Abstract
The experiment has been carriedto find the actual strength of glass plate which used as a building materials. This report consisted from following.
1. To find the uniform load using the samples which having different thickness and area.
2. To calculate the bending strength from above exp. and obtained the result as following.
730 kg/cm2 for 2mm. thickness.
560kg/cm2 for 3mm. thickness.
470kg/cm2 for 5mm. thickness.
420kg/cm2 for 6mm. thickness.
3. To calculate the hydrauric and wind pressure and then compared to the uniform load which obtaind by above experiment.
Content from these authors
© The Ceramic Society of Japan
Previous article Next article
feedback
Top