Journal of the Ceramic Society of Japan
Online ISSN : 1348-6535
Print ISSN : 1882-0743
ISSN-L : 1348-6535
Technical reports
Evaluation of joined silicon nitride by X-ray computed tomography (X-ray CT)
Naoki KONDOYoshihiro NISHIMURATakayuki SUZUKIHideki KITA
Author information
JOURNAL FREE ACCESS

2010 Volume 118 Issue 1384 Pages 1192-1194

Details
Abstract
X-ray computed tomography (X-ray CT) was performed to evaluate defects in a joined silicon nitride sample. The resolution of the X-ray CT was about 10 µm. ZrO2 particles (ZrO2 was added as a sintering additive), segregation of Zr, and cracks were successfully observed. These defects were most likely introduced during the fabrication procedure, i.e., by insufficient milling of the ZrO2, separation of ZrO2 in the slurry, and cracking during drying after slip-casting. X-ray CT is demonstrated to be a useful evaluation method, since these defects are introduced not only by joining but also by usual ceramics processing.
Content from these authors
© 2010 The Ceramic Society of Japan
Previous article Next article
feedback