1990 Volume 5 Pages 23-29
The purpose of this test construction of retaining wall reinforced with geotextiles was to ensure the application and to extract issues for design method under examination. The constructed retaining wall was based on this design method and was mesured the behavior for a long term.
As the result, it was found that this design method was available for the retaining wall. But, it was necessary to examine in detail about the spacing of reinforcement and the facing.