1991 Volume 6 Pages 33-43
Many studies have been made on leakage detection of waste disposal lined with geomembrane. But, there is no method to locate a leak point reliably.
We developed a leak point location system, based on 2 electrical techniques, phase detection and to make anisotropic electric conductivity of ground.
The purposes of this paper are: (i) to describe an outline of the system; (ii) to introduce 2 electrical approaches, phase detection technique and to make anisotropic electric conductivity of ground; (iii) to show some experimental results.