2001 Volume 16 Pages 191-198
The authors conducted a puncture test using a nail with a diameter of 3.7mm, a top angle of 15 degrees and length of 65mm for geomembrans and geotextiles placed on the compacted model ground with various corn resistance (qc).
The results obtained were compered with those obtained using a piston based on standard of ASTM D4833. Second, they also conducted a puncture tests using a nail for double-liner system. Last, they examined efficiency of estimating method proposed by O. Ariteres for our all results.