Abstract
Dynamic corrosion tests were carried out on a curved mild-steel pipe through which hydrochloric acid-solution was circulated at a constant velocity.
As a result, it was recognized that the corrosion behavior of a curved pipe depended largely upon the property of its hardened surface-layer produced by cold-working. And, a method was proposed to estimate the corrosion allowance or the lifetime of a pipe under a given operating condition.