TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
Originals
Treeing Characteristic of EPR for Solid Insulated Superconducting Cable
Atsushi MINODAYukio MIZUNOYuji MURAMOTONaohiro NOZUMIMasayuki NAGAOMasamitsu KOSAKI
Author information
JOURNAL FREE ACCESS

2003 Volume 38 Issue 10 Pages 554-559

Details
Abstract
Superconducting power cables are one of the promising ways for handling large volumes of electric power efficiently in the future. The authors have proved that ethylene-propylene rubber (EPR) is suitable for use as the solid electrical insulating material of superconducting cable due to its excellent mechanical and electrical properties at cryogenic temperature. It is therefore imperative to study EPR resistance to treeing in view of long-term reliability as a cable insulator. The objectives of this study were to examine EPR resistance to treeing both at liquid nitrogen and room temperatures and the effect of fillers on resistance to treeing. The results show that EPR has sufficient resistance to AC treeing at liquid nitrogen temperature and the fillers improve resistance to AC treeing slightly.
Content from these authors
© 2003 by Cryogenics and Superconductivity Society of Japan (Cryogenic Association of Japan)
Previous article Next article