Double-loop Thermoacoustic Stirling Cooler
- II. Measurements of Acoustic Streaming Velocity-
Tetsushi BIWA
Author information
JOURNAL FREE ACCESS

2008 Volume 43 Issue 12 Pages 543-547

Details
Abstract
In thermoacoustic devices with a looped tube, it has been pointed out that acoustic streaming circulating the loop leads to unwanted heat loss. In this research,, we measured the acoustic streaming velocity in a double-loop thermoacoustic Stirling cooler, and show that the streaming circulating the loop accounts for a heat loss of 150 W when input heat to the prime-mover loop is 408 W. It is also shown that the installation of an elastic membrane effectively suppresses the heat loss and thereby increases the performance of the prime-mover loop and cooler loop.
Content from these authors
© 2008 by Cryogenics and Superconductivity Society of Japan (Cryogenic Association of Japan)