2022 Volume 57 Issue 3 Pages 147-154
Type HT-NX series, DI-BSCCO tapes laminated with pre-tensioned nickel alloy foils for reinforcement, have higher strength than the other types of DI-BSCCO tapes. In this research, we measured the effect of cyclic tensile load of up to 105 cycles on the Ic degradation of 4 kinds of HT-NX tapes and a spliced tape by the original fatigue test system. The results indicated that Ic of HT-NX series tapes survive up to 105 cycles, if an applied cyclic maximum stress (stress ratio 0.1) is less than their own static irreversible stress. From observations of the same location of the longitudinal section during fatigue, a local crack from the BSCCO layer penetrating a few fatigued Ag pipes was found, while a crack in the BSCCO layer by static load with the same Ic degradation level was trapped by a Ag pipe. The damage to the Ag pipe is peculiar to the cyclic load.