TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
Temperature Profile Measurement in Cryogenic Fluid by Use of Si Diodes Matrix
Noriharu TAMADANaotake NATORIShuichiro FUCHINO
Author information
JOURNAL FREE ACCESS

1991 Volume 26 Issue 6 Pages 480-487

Details
Abstract

Temperature measurement is one of the most fundamental techniques to proceed cryogenic experiment. Especially, information on temperature distribution is quite useful to know flow pattern of nuclear boiling fluid. To carry out the distribution measurement, a large number of sensors are required accompanying with huge number of data transfer wires. However, the complex wirings always lead to poor reliability of the measurement system. This paper proposes a new method for temperature distribution measurement in cryogenic fluid with Si diodes matrix as thermo-sensors. The data scanning method is introduced to solve huge wirings problem. In the paper, 64 points (8×8) diodes matrix distrubution sensor is manufactured as a prototype system, which is operated in cryogenic GN2 flow to assess its availability.

Content from these authors
© Cryogenic Association of Japan
Previous article Next article
feedback
Top