Abstract
Experimnents were made on pressure drop of liquid nitrogen flow in concentric annuli. The Reynolds number based on hydraulic diameter and mean velocity ranged from 200 to 18, 000. As a result it was found that the relation between Reynolds number and friction factor showed good agreement with the data previously obtained for newtonian fluid at room temperature.