Three Cases of the Distal Periprosthetic and Extra-prosthetic Femoral Shaft Fracture Following Hip Arthroplasty
Hisashi OISHIHideo OKUMURAKohei ISHIMARUNaohiko MASHIMAKenji MATSUMOTOTaiho SHIBATAHideo KUSHIBEKenji TAKUBOMasataka YOKOTEKen SEIKEHiroto SOGABE
Author information
JOURNAL FREE ACCESS

1998 Volume 10 Issue 2 Pages 263-268

Details
Abstract
This report concerns three cases of distal periprosthetic and extra-prosthetic femoral shaft fracture following Hip Arthroplasty. According to the criteria of Johansson, one case was classified as a Type-II fracture and two cases were classified as Type-III fractures. These three fractures were treated with open reduction and internal fixation using the BMPTM Cable Plate System and the MayTM Anatomical Bone Plate. The BMPMT Cable Plate could be applied to fractures both above and below the prosthetic tip and provided immediate rigid fixation allowing early mobilization. We recommend the use of the BMPTM Cable Plate System for Type-II and Type-III fractures.