Journal of Disaster Research
Online ISSN : 1883-8030
Print ISSN : 1881-2473
ISSN-L : 1881-2473
Special Issue on Actions Toward Futuristic Urban Flood Risk Research and Management
Validation of Inundation Damage Reduction by a Pump Gate with the New Type of Horizontal Axial Submersible Pump
Kentaro FukumoriYu KuritaHiroaki Furumai
Author information
JOURNAL OPEN ACCESS

2021 Volume 16 Issue 3 Pages 381-386

Details
Abstract

Compared to pumping stations, pump gates have small sites and are constructed for a low cost over a short period of time. A new type of horizontal axial submersible pump that is optimal for pump gates has recently been developed. Since the new type of pump can be operated at full speed regardless of water level, it is possible to conduct standby operations in preparation for stormwater runoff inflows. In a simulation comparing the conventional pumps and the new type of pump, there was no serious inundation condition in the new pump up to 70 mm/h, which is 140% of the design’s rainfall intensity. As a result, it was clarified that standby operations can keep the peak water level low and maximize the water storage capacity of the drainage channel.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2021 Fuji Technology Press Ltd.

This article is licensed under a Creative Commons [Attribution-NoDerivatives 4.0 International] license (https://creativecommons.org/licenses/by-nd/4.0/).
The journal is fully Open Access under Creative Commons licenses and all articles are free to access at JDR Official Site.
https://www.fujipress.jp/jdr/dr-about/
Previous article Next article
feedback
Top