Journal of Flow Injection Analysis
Online ISSN : 2433-7374
Print ISSN : 0911-775X
Sequential Injection Spectrophotometric Determination of Cyanide
Original Paper
Abdalla AbulkibashSafwan Fraihat
Author information
JOURNAL FREE ACCESS

2007 Volume 24 Issue 1 Pages 17-

Details
Abstract
A simple and rapid sequential Injection spectrophotometric method for the determination of cyanide is proposed. The method is based on the reaction of cyanide with 2,2-dihydroxy-1,3-indanedione (Ninhydrin), which produces a red colored product that can be monitored at a wavelength of 600 nm. The linear range found is between 2.00 and 7.00 mg l-1 with a detection limit of 0.16 mg l-1. The sampling rate was calculated to be 45 samples per hour. The proposed method has a precision and accuracy comparable with standard methods.
Content from these authors
© 2007 Japanese Association for Flow Injection Analysis