Journal of Flow Injection Analysis
Online ISSN : 2433-7374
Print ISSN : 0911-775X
Fluorescence Detection-FIA for ppb Levels of Bromate with Trifluoperazine
Original Paper
Takao OhtomoRumi YatabeYoshiharu TanakaJun KatoShukuro Igarashi
Author information
JOURNAL FREE ACCESS

2009 Volume 26 Issue 2 Pages 127-

Details
Abstract

The fluorescence of tifluoperazine at EX:300 nm and EM:485 nm was changed into non-fluorescent substance in the presence of bromate under acidic conditions, and the fluorescence detection-FIA of trace amounts of the bromate was developed using this phenomenon. In the concentration range of 1-15 μg L-1, the bromate analysis was able to obtain a good straight line and eighteen samples per hour were measured. For 7.5 μg L-1 of bromate, the relative standard deviation(RSD) was 2.03 %(n=5) and the detection limit (3σ) was 1.47 μg L-1.

Content from these authors
© 2009 Japanese Association for Flow Injection Analysis