Journal of Fluid Science and Technology
Online ISSN : 1880-5558
ISSN-L : 1880-5558
Papers
A Study on Internal Flow in a New Type of Sewage Pump
(2nd Report, Influence of Impeller Blade Loading and Volute Casing)
Yasuyuki NISHINobuaki MATSUOJunichiro FUKUTOMI
Author information
JOURNAL FREE ACCESS

2009 Volume 4 Issue 3 Pages 661-672

Details
Abstract
Sewage pumps are designed with a wide flow channel by, for example, sacrificing some efficiency and reducing the number of blades, in order to prevent plugging with foreign bodies. Authors have been proposing a new type of sewage pump impeller designed to further improve pump efficiency and performance in passing foreign bodies. This sewage pump impeller has a structure in which the suction flow channel of closed type non-clog pump is wound in a helical spiral. The focus of this research was to investigate internal flow in this single blade sewage pump impeller by LDV measurement and CFD. As a result of having examined influence of impeller blade loading and volute casing, it clearly indicated the following facts. As well as influence of impeller blade middle loading and influence of the secondary flow, by increase of slip by influence of volute casing, static pressure and total pressure suddenly decrease together towards the end from impeller blade middle neighborhood.
Content from these authors
© 2009 by The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top