Japanese Geotechnical Journal
Online ISSN : 1880-6341
ISSN-L : 1880-6341
Papers
Study on the shape of freezing front and frost heave damage of Box-culvert structure
- Inspection by 2-dimensional FEM heat conduction analysis -
Keiji HAYASHITeruyuki SUZUKIKunio TOYOTA
Author information
JOURNAL FREE ACCESS

2009 Volume 4 Issue 2 Pages 147-156

Details
Abstract
A box culvert (C-Box) is placed over the road in order to allow traffic to cross over a small river or other roads. Currently, two types of frost heave damage in cold districts are being reported: cracks that are generated when the road surface, which is directly on the C-Box, is lifted like the mound, and cracks that are generated in the sidewall by the frost heaving pressure. In the investigation to determine the mechanism of these damages, we set an embankment model in a large-scale low temperature room, and compared the results of soil temperature measurements and those of 2-dimensional FEM heat conduction analysis. As the result of these experiments and analyses, the soil temperature distributions and progress of freezing fronts (0 degrees centigrade) in the soil around the C-Box were reproduced. It was revealed that frost entered the soil around the C-Box from the inside of the C-Box as well as from the surface of the embarkment, and this frost caused the shape of the freezing front to interfer with each other, which generated a bigger frost heave.
Content from these authors
© 2009 The Japanese Geotechnical Society
Previous article Next article
feedback
Top