The Interaction between Copper and Coronary Risk Indicators
Bahattin AdamSennur AslanAbdulkerim BedirMuhlisse Alvur
Author information
JOURNAL FREE ACCESS

2001 Volume 42 Issue 3 Pages 281-286

Details
Abstract
We studied the effects of external copper exposure on plasma copper, serum lipids, lipoproteins and apolipoproteins in workers who have excessive contact with copper. Fifty-eight healthy Turkish males who were working in the copper processing industry and 33 control subjects were examined. Copper concentration was measured by flame atomic absorption spectrometry, lipid and lipoprotein levels were detected by spectro- photometry and apolipoproteins were measured with a nephelometer.
There was no significant difference in plasma copper between the workers and the controls. However, in the worker group, the mean levels of TC, LDL-C, apoAI, apoB and Lp (a) were significantly higher while the mean level of HDL-C was significantly lower than that of the controls. In addition, there was a significant positive correlation between plasma copper and LDL-C only in the workers group.
Our findings suggest that excessive contact with copper may contribute to coronary risk factors.