Japanese Heart Journal
Online ISSN : 1348-673X
Print ISSN : 0021-4868
ISSN-L : 0021-4868
Clinical Studies
Sequential Evaluation of Left Ventricular Systolic and Diastolic Function After Radiofrequency Catheter Ablation
Abdurrahman EksikSevket GorguluMehmet ErenAhmet AkyolIzzet ErdinlerEnis OguzKadir GurkanTanju UluferTuna Tezel
Author information
JOURNAL FREE ACCESS

2004 Volume 45 Issue 3 Pages 429-440

Details
Abstract

Radiofrequency (RF) catheter ablation has become standard therapy for many types of arrhythmias. RF energy may cause deterioration in left ventricular function by damaging the myocardium. The aim of the present study was to assess the changes in left ventricular function after catheter ablation using various echocardiographic parameters.
Forty patients (22 women), aged 37 ± 14 years (range, 15-76 years), underwent catheter ablation for various tachycardias. Routine echocardiogaphic examination was done in all patients. Left ventricular systolic function was evaluated by the modified Simpson method and tissue Doppler. With regard to left ventricular diastolic function parameters, diastolic early (E) and late (A) transmitral filling velocities, deceleration time (DT), isovolumetric relaxation time (IVRT), and tissue Doppler parameters were assessed. All ventricular function parameters were assessed before, and 1 hour, 1 day, and 1 month after the catheter ablation procedure. To avoid any influence of heart rate on diastolic function parameters, the E/A ratio, DT, and IVRT were adjusted to heart rate (cE/A, cDT, cIVRT).
No changes in left ventricular systolic function after the ablation were observed. After the ablation procedure (1 hour, 1 day, and 1 month) the cE/A ratio decreased from 1.42 ± 0.43 to 1.19 ± 0.40, 1.18 ± 0.40, and 1.30 ± 0.33 (P = 0.009), respectively. cDT increased from 210 ± 54 to 272 ± 64, 255 ± 60, 240 ± 64 (P = 0.001), respectively. Likewise cIVRT increased from 113 ± 22 to 133 ± 54, 123 ± 27, 117 ± 19 (P = 0.007), respectively. Significant changes were also observed concerning tissue Doppler parameters in assessing diastolic function.
Although no significant changes were observed in systolic function after RF ablation, this procedure may have some detrimental effects on ventricular diastolic function para-meters.

Content from these authors
© 2004 by the Japanese Heart Journal