Japanese Heart Journal
Online ISSN : 1348-673X
Print ISSN : 0021-4868
ISSN-L : 0021-4868
Case Reports
Usefulness of a 6 Fr Right Judkins Catheter for Mechanically Extracting a Massive Intracoronary Thrombus From an Ectasic Right Coronary Artery
A report on two different cases of thrombectomy
Satoru OnodaMakoto MutohTetsuya IshikawaHiroshi SakamotoJunichi YamaguchiHisayuki OkadaTetsushi TsurusakiTakeyuki KubotaShinichiro TakizawaHidenori YagiChikara MoriHidetaka NagasawaTakahiro ShibataSatoru YoshidaKamon ImaiToshinobu HorieSeibu Mochizuki
Author information
JOURNAL FREE ACCESS

2004 Volume 45 Issue 4 Pages 673-678

Details
Abstract

In order to bail out the slow-flow phenomenon (slow flow) created by a massive thrombus in an ectasic right coronary artery, a thrombus was mechanically extracted with a 6 Fr right Judkins (JR) catheter, which proved to be more useful than a usual thrombectomy using a RescueTM PT system catheter (Rescue). In case 1, the Rescue was used in combination with thrombolysis but failed to alleviate the slow flow that was implicated in a large infarction. On the other hand, in case 2, aggressive thrombectomy with a 6 Fr JR catheter with an 8 Fr Amplatz guiding catheter successfully extracted the massive intracoronary thrombus, restoring good coronary flow. Therefore, mechanical extraction with a 6 Fr JR catheter is safe and useful in cases of massive thrombus when diffuse coronary artery ectasia complicates an acute myocardial infarction. In addition, this method should be applicable to cases of acute coronary syndrome with massive thrombus.

Content from these authors
© 2004 by the Japanese Heart Journal
Previous article Next article
feedback
Top